Sirius 3.1, stove & Permeter package, bungalow

£4,920.99

Energy Efficient Design | Wood Burning Stove. Schiedel offers a unique all-in-one system: a perfect union of wood stove & chimney, which is an ideal package if you are a self-builder or renovating your home. The Sirius 3.1 Log Burning Stove is a contemporary model that has a large front window and door and additional side windows for an impressive 180-degree view.

The Sirius stove achieves up to 82 % energy efficiency, delivering more heat with less wood, and is far more likely to heat larger rooms more efficiently than traditional radiators. The Sirius stove package perfectly combines the Schiedel Permeter chimney system, which allows air-tight installation, with the energy-efficient, stylish and space-saving wood stoves.

STOVE-HIGHLIGHTS

  • Highly efficient up to 82%! More heat, less wood
  • Highest European and National Standards – EN 13 240, DIN+, 1.BImSchV2, DiBt, 15a B-VG, NS 3058/3059
  • Easy to operate with a self-closing door and interlock system for igniting or cleaning purposes
  • 3 Windows for 180° view in the 3 model
  • Eco-friendly corpus paint resulting in environmentally friendly low smoke and low-emission colour
  • Adjustable legs to adapt to uneven surfaces

SYSTEM HIGHLIGHTS

  • Combustion air independent from the installation room, provided through the Permeter Smooth Air Chimney from the top, allows flexible placement
  • Due to the system solution, no separate air channel adaptor/ bypass is necessary.

IDEAL FOR TIMBER FRAME BUILDINGS SUCH AS LOG CABINS

  • Ceiling Box and Protect Box options for complete safety in timber-framed buildings.
  • Exceptional small distances to combustibles

SKU: Sirius Model 3G – Wood Burning Stove / Permeter Flue System – Bungalow
Details SIRIUS 1.1 SIRIUS 3.1
Width 522mm 522mm
Height 1208mm 1208 mm
Depth 382mm 382 mm
Output 6 kW 6 kW
Efficiency 80.8% 82%
Energy efficiency A+ A+
Weight 133 kg 130 kg
Air independent
Triple-air-connection

 

APPROVALS
EN 13 240
DIN+, BImSchV 2, CE
15a B-VG
NS 3058 / 3059
DEFRA EXEMPT
CLEARSKIES LEVEL 5

DEFRA exempt

In addition to meeting the requirements of Ecodesign for efficiency and emissions, all clearSkies certified appliances at Level 3 or above will also have been verified by the scheme administrator as meeting the requirements for Defra exemption.

Therefore you can be assured that our Sirius 1 and Sirius 3 models exceed the minimum requirements and are future proofed as well as approved on the Defra website to be installed in Smoke Control Areas

SMOKE CONTROL AREAS.

Many parts of the UK are smoke control areas where:

  • You cannot release smoke from a chimney
  • You can only burn authorised fuel, unless you use an appliance approved by Defra (also known as an ‘exempt appliance’ or ‘Defra approved appliance’)

In England you may have to pay a penalty of up to £300 if your chimney releases smoke in a smoke control area.

You can be fined up to £1,000 if you buy unauthorised fuel to use in an appliance that’s not approved by Defra.

Exempt appliances that can burn unauthorised fuels include our stove ranges:

Unauthorised fuels, such as wood, can only be burned in exempt appliances such as some boilers, cookers and stoves.

You must only use the types of fuel that the manufacturer says can be used in the appliance.

Find out if you live in a smoke control area

Contact your local council to find out if you live in a smoke control area. The environmental services department will be able to help you.

What you can burn in smoke control areas

In a smoke control area you can only burn fuel on the list of authorised fuels, or any of the following ‘smokeless’ fuels, unless you’re using a Defra approved appliance:

  • Anthracite
  • Semi-anthracite
  • Gas
  • Low volatile steam coal

DEFRA EXEMPT OR “APPROVED”.

The Department for Environment, Farming and Rural Affairs (DEFRA) conducts assessments of stoves to evaluate their emissions and smoke output. A DEFRA exemption indicates that a stove has successfully undergone stringent testing and is approved for burning wood in designated smoke control zones.

The word “approved” is sometimes used, but this is informal and refers to the listings available on the DEFRA site.

THE IMPORTANCE OF USING DRY WOOD.

We always recommend that only logs with a moisture content below 20% should be used in a stove. Burning wet wood will lead to an increase in smoke and emissions and produce very little heat. It will also lead to the blackening of the stove glass and a build-up of soot in the chimney. Always look out for retailers with the official Woodsure “Ready to brun” logo. Find further information at the SIA website here.

INSTALLING A STOVE WITH A CHIMNEY SYSTEM.

We provide a complimentary chimney design service tailored to your specifications.

To take advantage of this service, please click here. Additionally, we offer guidance on installation types, with examples available on this page.

For locating a qualified installer, we suggest selecting a registered installer from the following schemes:

HETAS
BPEC
OFTEC

Alternatively, if this is part of a renovation or new build project, the installation can be signed off by Building Control.

BUILDING CONTROL – DOC J

It is important to note that if the stove is installed using a non-approved flue package, the warranty will be limited to one year. However, with a Schiedel Chimney System (your installer can provide recommendations on the appropriate type), the warranty extends to ten years.